Understanding BOD & COD: Beyond the Numbers
The real meaning of BOD & COD-Treat the problems, not the numbers

In the world of wastewater treatment, BOD (Biochemical Oxygen Demand) and COD (Chemical Oxygen Demand) are the most prominent parameters that are considered as pollution indicators. Treated as villains on an EHS dashboard—targets to be brought down, values to be minimized. But what do these numbers truly represent? What kind of organics do they qualify, and more importantly, who in the microbial world is responsible for bringing them down?

Many experts associate these with bod and cod in wastewater practices and their real impact on treatment efficiency.

Effluent treatment is not just a numbers game. It’s a microbial battleground—a complex “tug of war” between different microbial groups vying for pollutants/substrates, adapting to environmental pressures, and working together (or competing) to mineralize organics. In this blog, we explore the microbiological nuances behind bod and cod removal, how substrate complexity affects microbial degradation, and why a high COD isn’t always as alarming as it appears.

Understanding BOD and COD analysis can help in refining real-time operations and system design. Reach out to us to discover how advanced microbial solutions can optimize BOD and COD reduction while improving overall treatment efficiency.

The Basics: What BOD and COD Really Measure?

Before we dive into the microbial dynamics, let’s clarify the distinction.

BOD (Biochemical Oxygen Demand) is the amount of oxygen aerobic microbes require to degrade the organic matter, while COD (Chemical Oxygen Demand) quantifies the total oxygen equivalent required to chemically oxidize all organic matter (biodegradable + non-biodegradable) using a strong oxidizing agent like potassium dichromate.

These two are the cornerstone parameters in industrial wastewater treatment systems and compliance monitoring.

BOD < COD always, because COD includes organics that microbes simply cannot digest or take longer to degrade.

The bod cod ratio offers deeper insight into treatment feasibility and system design.

From an EHS perspective: High COD indicates total organic pollution load, while high BOD reflects readily biodegradable organics. Both values are essential to understand how much pollution is treatable biologically and what might need polishing steps or advanced oxidation.

Tracking wastewater parameters like BOD and COD regularly can optimize the sewage treatment process.

Microbes on the Frontline: Who Eats What?

In biological treatment, different microbes have different dietary preferences. Let’s break down the microbial players and the type of organics they typically handle:

Microbe Type Preferred Substrates Typical Zone
Heterotrophic bacteria Simple organics: sugars, alcohols, VFAs Aerobic & Anoxic
Autotrophs (e.g., nitrifiers) Ammonia and nitrite (not BOD/COD reducers) Aerobic
Facultative bacteria Complex and simple organics Facultative zones
Anaerobic consortia Proteins, lipids, cellulose (via hydrolysis → VFAs) Anaerobic digesters
Fungi Lignin, dyes, complex non-biodegradable organics Low-pH, low-DO

These microbial consortia play a vital role in bioaugmentation and microbial treatment in wastewater.

The ability of microbes to remove BOD and COD depends heavily on the complexity of the organic compounds:

  • Simple organics (low molecular weight): Easily removed in an activated sludge or aerobic digestion process.
  • Complex organics (e.g., phenolics, surfactants, dyes, oils): Require anaerobic process and longer retention time.

Effective treatment starts by understanding the organic load in wastewater and choosing the right microbial tools.

Substrate Complexity: Why It Matters

Not all COD is equal. Consider this:

A sugar-rich food processing effluent with COD 6000 ppm may have a BOD/COD ratio of 0.8 – meaning most of it is biodegradable.

A dye-laden textile effluent with the same COD might have a BOD/COD ratio of 0.2—signifying poor biodegradability.

Such complex effluents need multi-stage biological systems or pre-treatment with specific cultures.

Key Insight:

The BOD/COD ratio is a more insightful metric than standalone COD. Ratios:

  • 0.6: Easily biodegradable
  • 0.4–0.6: Moderately biodegradable
  • <0.4: Poorly biodegradable; may need physico-chemical treatment

In wastewater management, this ratio informs engineers whether nutrient removal or advanced oxidation is required.

Why High COD Isn’t Always Bad?

Let’s bust a common myth:

“High COD = Bad effluent” is not always true.

Imagine a brewery effluent with COD 20,000 ppm. That’s high, but it’s primarily from sugars, alcohols, and yeast residues—all highly biodegradable. A well-seeded biological reactor can bring it down to <200 ppm BOD with minimal retention time.

This shows how biodegradable wastewater with high COD still allows for efficient treatment if the microbial ecosystem is well-managed.

The issue isn’t how much COD, but:

  • What kind of organics are present?
  • Are they toxic to microbes?
  • What is the system design (anaerobic first, aerobic polishing, etc.)?

This is where environmental monitoring and EHS in wastewater become indispensable.

Winning the Microbial Tug of War

If COD removal is a tug of war, here’s how to tip the balance:

  • Pre-treatment & Equalization: pH adjustment, oil & grease removal, and flow equalization prevent microbial shocks.
  • Segmented Treatment Zones: Anaerobic → Anoxic → Aerobic → Polishing ensures sequential degradation of complex substrates.
  • Use of Custom Biocultures: Tailored microbial blends (like lignin-degraders or surfactant–eaters) enhance specific removal.
  • Nutrient Balancing: C:N:P ratio is essential. Too much carbon without nitrogen/phosphorus slows down microbial growth.
  • Monitoring & Feedback: Online DO, ORP, and real-time COD analyzers help in dynamic adjustment

Each of these is critical for maintaining optimal microbial load and ensuring full biological oxygen demand reduction.

Final Thought: Treating the Problem, Not Just the Number

COD and BOD are not just compliance metrics—they are windows into the microbial and chemical world inside your ETP. A high COD is only dangerous if:

  • It overwhelms the biological system
  • It contains toxins
  • Or it is mismanaged

With the right microbial consortia, proper process staging, and continuous EHS vigilance, even high-COD effluents can be efficiently treated—transforming a ‘problematic’ effluent into a sustainable output.

This makes bod cod full form far more than a definition—it’s a philosophy for modern types of wastewater management.

After all, in the tug of war between pollution and treatment, it’s the micro-warriors who win it for us—if we give them the right battlefield.

Team One Biotech is one of the leading Biotech Companies in India, providing advanced microbial solutions like bacteria for ETP treatment and bacteria culture for wastewater treatment.
???? Reach out now to enhance your wastewater treatment efficiency.

???? Email: sales@teamonebiotech.com

???? Visit: www.teamonebiotech.com

???? Discover More on YouTube – Watch our latest insights & innovations!-

???? Connect with Us on LinkedIn – Stay updated with expert content & trends!

Understanding Recalcitrant COD in Wastewater Treatment

Wastewater treatment plants (WWTPs) are designed to remove organic pollutants, typically measured as chemical oxygen demand (COD). However, not all COD is easily degradable. A significant portion, known as recalcitrant COD, poses a major challenge for treatment facilities due to its resistance to conventional biological treatment methods. If you’re looking for effective solutions to tackle recalcitrant COD in wastewater treatment, feel free to contact us.

What is Recalcitrant COD?

Recalcitrant COD consists of complex organic compounds that persist in the environment and do not break down easily by microbial activity. These compounds include industrial dyes, pesticides, phenols, pharmaceuticals, and certain synthetic chemicals. Their persistence in treated effluent can lead to environmental pollution and regulatory non-compliance. The removal of recalcitrant pollutants often requires integrating advanced oxidation processes with conventional wastewater treatment techniques to achieve highly efficient degradation.

Sources of Recalcitrant COD

Recalcitrant COD is commonly found in wastewater from industries such as:

  • Textile & Dyeing – Synthetic dyes and pigments (textile service)
  • Pharmaceuticals – Active drug ingredients (pharma service)
  • Petrochemicals – Hydrocarbons and solvents (chemical service)
  • Pulp & Paper – Lignin and chlorinated compounds (pulp & paper service)
  • Adhesives, Food, Dairy, Pesticides, and Rubber Industries – Contaminants from production and processing (adhesives service, food service, dairy service, pesticides service, rubber service)
Conclusion

Addressing recalcitrant COD is critical for achieving stringent waste water discharge standards and ensuring environmental sustainability. By integrating advanced oxidation processes with conventional biological treatment methods, industries can effectively reduce the environmental impact of their wastewater. Continuous research and innovation in water and wastewater treatment will pave the way for more highly efficient and cost-effective solutions.

For expert solutions in recalcitrant COD removal, consult with bioculture companies for wastewater treatment that provide customised culture and technical support tailored to industrial needs.

Are you dealing with recalcitrant COD in wastewater treatment? Contact us today to explore advanced treatment technologies tailored to your needs!

???? Email: sales@teamonebiotech.com
???? Visit: www.teamonebiotech.com

???? Discover More on YouTube – Watch our latest insights & innovations!-

???? Connect with Us on LinkedIn – Stay updated with expert content & trends!

Bioculture-Based Treatment of Recalcitrant COD
Bioculture-Based Treatment of Recalcitrant COD in Pharmaceutical Effluents
Introduction

It often happens that an Effluent Treatment Plant’s (ETP) chemical oxygen demand (COD) degrading efficiency becomes stagnant at a certain point. Despite trying multiple wastewater treatment methods and technologies, breaking this threshold remains a challenge. The real culprit behind such scenarios is the presence of recalcitrant COD in pharma effluents.

Pharmaceutical wastewater, in particular, presents high COD and BOD challenges due to persistent Active Pharmaceutical Ingredients (APIs), solvents, and excipients that resist biological treatment. Conventional systems often struggle to meet regulatory compliance, making microbial culture-based treatment a promising alternative. This blog explores treatment efficiency, plant configurations, cost analysis, and pilot project insights for implementing enzyme-based bioculture in pharma effluent treatment.

To learn more about effective solutions for reduction of recalcitrant COD reduction in Pharmaceutical Effluents, feel free to contact us.

1. Understanding Bioculture-Based Treatment for Pharma Effluent
How Biocultures Work?

Microbial culture is a specialized microbial consortia capable of degrading recalcitrant COD through enzymatic breakdown. They work via:

Advanced oxidation processes – Breaks complex organic compounds into biodegradable intermediates. 

Co-Metabolism – Uses an additional carbon source to enhance pollutant degradation. 

Biofilm Formation – Protects microbes from toxic compounds and improves stability in treatment systems.

Targeted Degradation of Recalcitrant COD Components
Pharma Compound Common Source Microbial Strains Used Enzymes Involved Degradation Pathway
Paracetamol Painkillers Pseudomonas putida, Bacillus subtilis Amidase, Laccase Amide hydrolysis to p-aminophenol, oxidation
Ibuprofen & Diclofenac NSAIDs Sphingomonas sp., Rhodococcus sp. Dioxygenases, Hydrolases Hydroxylation & carboxylation of aromatic rings
Ciprofloxacin & Ofloxacin Antibiotics Acinetobacter sp., Pseudomonas aeruginosa Monooxygenases Quinoline ring cleavage
Erythromycin & Azithromycin Macrolide Antibiotics Bacillus licheniformis Esterase, Oxidase Ester bond hydrolysis, oxidation
Estradiol & Progesterone Hormones Comamonas testosteroni, Mycobacterium sp. Hydroxylase, Dehydrogenase Steroid ring hydroxylation
Chloramphenicol Antibiotics Pseudomonas fluorescens Reductase, Hydrolase Nitro group hydrolysis
Azo Dyes (Erythrosine, Tartrazine) Coloring Agents Pseudomonas aeruginosa, Shewanella oneidensis Azoreductase Azo bond cleavage
Nonylphenols, PEGs Surfactants Sphingomonas sp., Pseudomonas sp. Oxidase, β-Oxidase Oxidation of alkyl chains
2. Treatment Systems Configurations Using Biocultures
Plant Design for Pharma Wastewater Treatment Process
Stage 1: Pre-Treatment (Equalization & Primary Treatment)

Objective: Remove suspended solids, neutralize pH, and reduce initial COD load.

Equalization Tank – Balances flow & pH (6.5–7.5).
Coagulation-Flocculation – Removes large particulates (e.g., PAC or FeCl₃).
Screening & Oil Removal – Eliminates large solids and oil residues.

Stage 2: Advanced Biological Treatment with Microbial Culture

✅ Moving Bed Biofilm Reactor (MBBR) or Sequential Batch Reactor (SBR) – Bioculture for STP wastewater treatment

✅ Optimized Microbial Seeding – Customised culture for targeted degradation. 

✅ Retention Time: 24–36 hours for reaction time.

Stage 3: Advanced Oxidation Processes & Membrane Filtration 

Fenton’s Process / Ozonation – Further breaks down recalcitrant COD

Membrane Bioreactor (MBR) or Reverse Osmosis (RO) – Final purification.

Stage 4: Sludge Management & Water Reuse

✅ Dewatering & Sludge Handling – Using filter press or centrifugation. 

✅ Effluent Recycling – Treated water reused for lagoons wastewater treatment.

3. Pilot Project Insights: Real-World Applications
Case Study 1: Antibiotic Manufacturing Effluent Treatment

???? Location: India | COD Level: 10,000 mg/L

✅ Solution: Bioculture companies for wastewater treatment (Acinetobacter sp. & Pseudomonas sp. in MBBR). 

✅ Result:

  • COD reduced by 85% (Final COD: <500 mg/L).
  • Reduced toxicity – No microbial inhibition observed.
Case Study 2: NSAID (Ibuprofen & Diclofenac) Removal

???? Location: Europe | COD Level: 8000 mg/L
✅ Solution: SBR + Microbial Culture Companies in India (Rhodococcus + Sphingomonas). 

✅ Result:

  • COD reduced by 90% (Final COD < 250 mg/L).
  • High removal of Ibuprofen (96%) & Diclofenac (89%).
4. Cost Analysis of Bioculture-Based Treatment
Cost Component Estimated Cost (₹/m³) Description
Bioculture Seeding ₹3–6 Initial inoculation for microbial growth
Reactor Operation (MBBR/SBR) ₹15–20 Aeration, energy, and microbial maintenance
AOP (Ozonation/Fenton’s Process) ₹8–12 Advanced oxidation for recalcitrant organics
Membrane Treatment (RO/MBR) ₹12–18 Filtration and final polishing
Total Treatment Cost ₹38–56 per m³ Cost-effective compared to ZLD (₹80-100 per m³)
Key Takeaways:
  • Bioculture-based treatment reduces overall cost by 30–50% compared to purely chemical or ZLD systems.
  • Lower sludge production compared to coagulation-based treatments.
  • Faster startup time (2–3 weeks) compared to conventional activated sludge.
Conclusion: The Future of Biocultures in Pharma Effluent Treatment

???? Bioremediation companies in India offer a sustainable & cost-effective solution for treating recalcitrant COD in pharma effluents.
???? Bioculture companies in India can provide enzyme-based bioculture tailored for specific APIs, ensuring high pollutant removal.
????  Integrating biocultures with advanced oxidation & MBBR/SBR technology enhances efficiency & meets regulatory standards.

If you’re looking for expert guidance or customized solutions for your ETP, our team is here to help!

Contact us today for a consultation or to learn more about how we can support your effluent treatment needs!

???? Email: sales@teamonebiotech.com

???? Visit: www.teamonebiotech.com

???? Discover More on YouTube – Watch our latest insights & innovations!-

???? Connect with Us on LinkedIn – Stay updated with expert content & trends!

Impacts of Ammoniacal Nitrogen in Water and Wastewater
Impacts of Ammoniacal Nitrogen in Water and Wastewater

Ammoniacal nitrogen (NH₄⁺-N) is a crucial water quality parameter that influences aquatic ecosystems, wastewater treatment processes, and industrial effluent management. High concentrations can pose severe environmental risks and operational challenges for municipal wastewater treatment plants, industrial wastewater systems, and agricultural runoff management. Effective bioculture for wastewater treatment is essential to mitigate these impacts.

???? Visit: www.teamonebiotech.com/contact-us

1. Environmental Impacts

Toxicity to Aquatic Life – Free ammonia (NH₃) is toxic to fish and other aquatic organisms, affecting respiration, and metabolism. Even low levels (≥0.1 mg/L NH₃-N) can be harmful.

Oxygen Depletion – Ammonia oxidation (nitrification) consumes dissolved oxygen (DO), leading to hypoxia and potential fish kills.

Eutrophication – Excess nitrogen compounds, including ammonium ions, contribute to algal blooms, reducing oxygen levels and degrading surface water quality.

pH Alteration – Ammonia can raise water pH, making it unsuitable for sensitive aquatic ecosystems, including freshwater lakes, wetlands, and coastal waters.

2. Wastewater Treatment Challenges

Inhibited Biological Treatment – High ammonia concentrations can inhibit nitrifying bacteria, disrupting biological nitrogen removal (BNR) and anaerobic digestion processes. Bioculture for wastewater plays a vital role in restoring microbial balance.

Increased Operational Costs – Advanced ammonia removal technologies, such as nitrification-denitrification, ion exchange, and chemical precipitation, require aeration energy, monitoring systems, and chemical dosing, increasing wastewater treatment costs.

Sludge Bulking & Foaming – Ammonia fluctuations can disturb the microbial community balance, leading to poor sludge settling, filamentous bulking, and foam formation in activated sludge systems.

3. Regulatory & Public Health Concerns

Drinking Water Contamination – Excess ammonia can lead to nitrite formation, posing a risk of methemoglobinemia (“blue baby syndrome”), particularly in infants and pregnant women.

Stringent Discharge LimitsEnvironmental regulations, such as those set by the EPA, CPCB, and EU Water Framework Directive, impose strict ammonia discharge limits to prevent groundwater pollution, surface water degradation, and ecological imbalances. Industries must implement efficient wastewater treatment solutions, including biological treatment, physico-chemical processes, and customized bio cultures for wastewater treatment.

Conclusion

Managing ammoniacal nitrogen in wastewater effluents is essential to protect natural water bodies, ensure regulatory compliance, and maintain efficient treatment plant operations. Implementing advanced ammonia removal methods, such as bioculture for wastewater, bioaugmentation, membrane bioreactors (MBR), and electrochemical oxidation, can help achieve sustainable nitrogen management in municipal and industrial wastewater treatment plants.

Are you looking for a reliable bioculture company in india?

???? Discover More on YouTube – Watch our latest insights & innovations!
???? Connect with Us on LinkedIn – Stay updated with expert content & trends!

???? Contact us today to explore customized bioremediation strategies for your industry!
???? Email: sales@teamonebiotech.com
???? Visit: www.teamonebiotech.com/contact-us

Aerobio – Microbial Cultures, Bio Product, Bacteria with Enzymes, Bacterial Culture, Digester Treatment

Since aerobic digestion is an integral and important step in wastewater treatment, the health status of activated sludge becomes a fundamental concern for any industrial WWTP or ETP management.

T1B Aerobio is a trustworthy aid to maintain the functionality and productiveness of any wastewater treatment process. T1B Aerobio is tenacious in breaking down organic matter and reducing the biological oxygen demand (BOD) or chemical oxygen demand (COD) levels in wastewater.

With its exceptional tendency to remain conducive even with fluctuating temperature ranges, unstable pH levels, and escalated levels of total dissolved solids or TDS, the T1B Aerobio is a quintessential addition to a wastewater treatment process.

Recalcitrant compounds are hard to degrade chemical substances. Adding T1B Aerobio in sludge waste fortifies the degradation of these harmful compounds. T1B Aerobio is also a robust bioproduct that decomposes xenobiotic compounds effectively. Use of T1B Aerobio will definitely improve the efficiency of various biological process and units like, ASP, MBR, MBBR, SBR, RBC, Trickling Filter. etc. It works under suspension mode as well as attached mode systems.

T1B Aerobio | Microbiome Solution For Aerobic Digestion – Efficient For Reduction Of BOD and COD in wastewater for reclacitrant and xenobiotic compounds

Aerobic Microbial Cultures – Aerobic Bio Product – Aerobic Bacteria With Enzymes – Aerobic Bacterial Cultures – Aerobic Digester Treatment – Wastewater Bioremediation – Bioremediation – Bioaugmentation – Bio Product – High COD/BOD – High Ammoniacal Nitrogen – High TDS – Tough To Biodegrade Efflunet – Xenobiotic Compounds – Reclacitrants – Oil & Grease – Activated Sludge Process – ASP – Microbial Process – Oxygenation – Carbon Dioxide – Nutrient Removal – Aerobic Microorganisms – Sludge Reduction – Secondary Treatment – Respiration – Oxidation – Air Supply – Energy Efficiency – Carbon Footprint – Environmental Benefits – BOD (Biochemical Oxygen Demand) – COD (Chemical Oxygen Demand) – Aeration Tank – Activated Sludge – Activated Sludge Process – SBR (Sequential Batch Reactor) Process – MBR (Membrane BioReactor) Process – MBBR (Moving Bed Biofilm Reactor) process – RBC (Rotating Biological Contactor) Process – MBR-IFAS (Integrated Fixed-film Activated Sludge) Process – ASP (Aeration Stabilization Process) – Extended Aeration Process – Oxidation Ditch Process – Trickling Filter Process – High-Rate Trickling Filter Process – Submerged Aerated Filter Process – Membrane Aerated Biofilm Reactor (MABR) – Biofilm Reactors – Effective Microbes – Effective Microorganisms – High Strength CFU Per Gram – Industrial Wastewater Treatment – ETP – Efflunet Treatment Plant – CETP – Common Effluent Treatment Plant – Improve MLSS – Reduce Aeration – Plant Stability – Enhance Nitrogen And Phosphorus Removal – Commissioning Time of ETP – Rapid Growth Of MLSS and MLVSS – Shock load Stabilization – Overall Cost Of Operation – Faster Commissioning – Reduce COD BOD Ammoniacal Nitrogen – Improved Setteling – Colour Reduction – Aromatic Compounds Cellulose Proteins lignin lipids – High TDS Tolerant – Food Industry Effluent – Beverage Industry Wastewater – Dairy Industry Effluent – Meat Processing Industry – Paper Industry Effluent – Pharmaceutical Industry Effluent – Effluent From Textile Units – Effluent From Chemical Manufacturing Units – Dyes and Colorants Effluent – Detergents Effluent – Active Bioremediation

STP – Odour Control, Odour Reduction, Cheap BIoproducts, Powder Bioproduct, Liquid Bioproduct, Bio Culture For Sewage Treatment Plant

Several factors can undermine the effectiveness and efficiency of a sewage treatment plant. Factors such as composition (high levels of organic matter, nutrients or toxicity) of sewage wastes, higher temperatures that can reinforce microbial activity that breaks down organic sludge, hydraulic retention time, adequate oxygen supply to support microbial growth, and appropriate alkalinity of wastewater are among the most common ones.

It naturally becomes vital that any microbial formulation added to any STP can work through these variables. Team One Biotech’s “T1B STP” is a consortium of resilient & robust bacteria that facilitate the biodegradation of sewage wastes & organic pollutants by converting them into carbon dioxide, water and smaller biodegradable compounds.

T1B STP controls the formation of excessive organic sludge by rapidly degrading it. It also improves the settling rate of activated sludge for filtration and settling processes.

Longer retention time although allows for a more thorough treatment, it also increases the risk of odours and the growth of harmful organisms. T1B STP specializes in controlling filamentous bacterial growth in sewage management and also eliminates odours.

With its many beneficial properties like the high potency of reducing BOD, COD and ammonia, improving conditions for better floc formations, and controlling sludge bulking and excess foaming T1B STP applications are many. T1B STP microbial formulation can be used in any sewage treatment plant, sewer lines, STP pumping stations, municipal waste disposals and even for compact plants in housing complexes, hospitals etc.

T1B STP | Bacteria Consortia For Sewage Treatment Plant (STP) – For Sewage Odor Control, Organic Sludge Reduction, Sludge Bioremediation

STP Odour Control – Odour Reduction In STP – Cheap Bioproducts For STP – Powder Bioproduct For STP – liquid Bioproduct For STP – Bio Culture For Sewage Treatment Plant (STP) – Powder Stp Sewage Treatment Plant Bio Culture – Bio STP – STP Culture – STP Bio Culture – Sewage Treatment Plant Chemicals – Biological Culture For Sewage Treatment Plant – Sewage Treatment Plant – Sewage Treatment – Biocultures For Sewage – Sewage Biocultures – Sewage Bacteria – Microbial Product For Sewage Treatment – Sewage Bioremediation – Odour Control In Sewage – STP Odour Control – Sludge Reduction – Reuse Of Sewage – Grey Water Treatment – Black Water Treatment – Sludge Reduction – Electricity Savings – Chemical For Sewage Treatment – Urine Treatment – FOG In Sewage – Bio Treatment Of Sewage – Sewage Sludge – Activated Sludge – Microbial Consortia – Microbial Inoculants – Bioreactor – Anaerobic Digestion – Nutrient Removal – Ammonia Oxidation – Denitrification – Phosphorus Removal – Microbial Enzymes – Biosurfactants – Aerobic Bacteria – Anaerobic Bacteria – Facultative Bacteria – Bio Enzyme – Enzymes – COD Removal – BOD Removal – Ammoniacal Nitrogen Removal – Sludge Degradation – Removing Oils, Fats And Grease – Reduces Aeration Requirement – Enzyme Producing Microbes – Enzyme Producing bacteria – Naturally Occurring Microbes – Bio Culture Bacteria Solutions – Enzyme Solutions – Bio Enhancer – Microbial Inoculum – Probiotic Bacteria – Municipal Waste Water Treatment – Bioculture Product – MLSS Development – Eco-Friendly Method Of Sewage Treatment

Scan the code